Stellarex drug-coated balloon featuring EnduraCoat technology comprising hybrid coating, Polyethylene glycol (PEG) excipient and 2µg/mm² low drug dose. Proven safety and efficacy in SFA.

Features
Effective low drug dose matters
Effective low drug dose matters

Effective low drug dose matters

Dose excess and particulate downstream possibly results in a delay of wound healing, loss of microcirculation and creation of aneurysms¹⁰⁻¹³. Stellarex is the only low dose DCB with a statistically significant treatment effect in femoropopliteal lesions².
Proven performance in calcium
Proven performance in calcium

Proven performance in calcium

PEG forms strong ionic bonds with hydroxyl apatite (HAp), the primary component of calcified atherosclerotic lesions¹⁴. PEG’s affinity for HAp may result in limited PTX washout in the presence of calcium.
Sustained tissue Residency
Sustained tissue Residency

Sustained tissue Residency

Hybrid paclitaxel offers prompt drug transfer and sustained tissue residency through 28 day restenotic window¹⁵⁻¹⁶.

Specifications

Product Catalog Number AB35SX060040135
Product Catalog Number AB35SX060040135
Balloon length
  • 40 mm
Nominal pressure
  • 8 atm
Rated burst pressure
  • 14 atm
Shaft length
  • 135 mm
Sheath size
  • 6F
Balloon diameter
  • 6 mm
Product Catalog Number AB35SX050040080
Product Catalog Number AB35SX050040080
Shaft length
  • 80 mm
Rated burst pressure
  • 18 atm
Balloon diameter
  • 5 mm
Nominal pressure
  • 10 atm
Sheath size
  • 6F
Balloon length
  • 40 mm
Product Catalog Number AB35SX040040080
Product Catalog Number AB35SX040040080
Rated burst pressure
  • 20 atm
Shaft length
  • 80 mm
Nominal pressure
  • 10 atm
Balloon diameter
  • 4 mm
Balloon length
  • 40 mm
Sheath size
  • 6F
Product Catalog Number AB35SX060040080
Product Catalog Number AB35SX060040080
Nominal pressure
  • 8 atm
Balloon diameter
  • 6 mm
Rated burst pressure
  • 14 atm
Balloon length
  • 40 mm
Shaft length
  • 80 mm
Sheath size
  • 6F
Product Catalog Number AB35SX040120080
Product Catalog Number AB35SX040120080
Rated burst pressure
  • 20 atm
Nominal pressure
  • 10 atm
Sheath size
  • 6F
Balloon length
  • 120 mm
Balloon diameter
  • 4 mm
Shaft length
  • 80 mm
Product Catalog Number AB35SX060120080
Product Catalog Number AB35SX060120080
Rated burst pressure
  • 12 atm
Shaft length
  • 80 mm
Sheath size
  • 6F
Nominal pressure
  • 8 atm
Balloon diameter
  • 6 mm
Balloon length
  • 120 mm
Product Catalog Number AB35SX040100135
Product Catalog Number AB35SX040100135
Balloon diameter
  • 4 mm
Sheath size
  • 6F
Nominal pressure
  • 10 atm
Rated burst pressure
  • 20 atm
Shaft length
  • 135 mm
Balloon length
  • 100 mm
Product Catalog Number AB35SX050100080
Product Catalog Number AB35SX050100080
Shaft length
  • 80 mm
Nominal pressure
  • 10 atm
Rated burst pressure
  • 18 atm
Balloon diameter
  • 5 mm
Balloon length
  • 100 mm
Sheath size
  • 6F
Product Catalog Number AB35SX050100135
Product Catalog Number AB35SX050100135
Sheath size
  • 6F
Shaft length
  • 135 mm
Rated burst pressure
  • 18 atm
Nominal pressure
  • 10 atm
Balloon length
  • 100 mm
Balloon diameter
  • 5 mm
Product Catalog Number AB35SX050120080
Product Catalog Number AB35SX050120080
Sheath size
  • 6F
Rated burst pressure
  • 16 atm
Balloon length
  • 120 mm
Balloon diameter
  • 5 mm
Shaft length
  • 80 mm
Nominal pressure
  • 10 atm
Product Catalog Number AB35SX060060080
Product Catalog Number AB35SX060060080
Shaft length
  • 80 mm
Nominal pressure
  • 8 atm
Balloon length
  • 60 mm
Rated burst pressure
  • 14 atm
Balloon diameter
  • 6 mm
Sheath size
  • 6F
Product Catalog Number AB35SX060080135
Product Catalog Number AB35SX060080135
Rated burst pressure
  • 14 atm
Sheath size
  • 6F
Balloon length
  • 80 mm
Balloon diameter
  • 6 mm
Nominal pressure
  • 8 atm
Shaft length
  • 135 mm
Product Catalog Number AB35SX040100080
Product Catalog Number AB35SX040100080
Balloon diameter
  • 4 mm
Shaft length
  • 80 mm
Nominal pressure
  • 10 atm
Sheath size
  • 6F
Balloon length
  • 100 mm
Rated burst pressure
  • 20 atm
Product Catalog Number AB35SX040060135
Product Catalog Number AB35SX040060135
Sheath size
  • 6F
Balloon diameter
  • 4 mm
Nominal pressure
  • 10 atm
Rated burst pressure
  • 20 atm
Shaft length
  • 135 mm
Balloon length
  • 60 mm
Product Catalog Number AB35SX050080135
Product Catalog Number AB35SX050080135
Balloon diameter
  • 5 mm
Rated burst pressure
  • 18 atm
Sheath size
  • 6F
Shaft length
  • 135 mm
Nominal pressure
  • 10 atm
Balloon length
  • 80 mm
Product Catalog Number AB35SX050080080
Product Catalog Number AB35SX050080080
Balloon diameter
  • 5 mm
Rated burst pressure
  • 18 atm
Nominal pressure
  • 10 atm
Shaft length
  • 80 mm
Balloon length
  • 80 mm
Sheath size
  • 6F
Product Catalog Number AB35SX040080080
Product Catalog Number AB35SX040080080
Balloon length
  • 80 mm
Shaft length
  • 80 mm
Nominal pressure
  • 10 atm
Rated burst pressure
  • 20 atm
Sheath size
  • 6F
Balloon diameter
  • 4 mm
Product Catalog Number AB35SX060100135
Product Catalog Number AB35SX060100135
Nominal pressure
  • 8 atm
Shaft length
  • 135 mm
Balloon length
  • 100 mm
Sheath size
  • 6F
Balloon diameter
  • 6 mm
Rated burst pressure
  • 14 atm
Product Catalog Number AB35SX060120135
Product Catalog Number AB35SX060120135
Rated burst pressure
  • 12 atm
Balloon diameter
  • 6 mm
Sheath size
  • 6F
Nominal pressure
  • 8 atm
Balloon length
  • 120 mm
Shaft length
  • 135 mm
Product Catalog Number AB35SX040080135
Product Catalog Number AB35SX040080135
Balloon length
  • 80 mm
Balloon diameter
  • 4 mm
Shaft length
  • 135 mm
Rated burst pressure
  • 20 atm
Nominal pressure
  • 10 atm
Sheath size
  • 6F
Product Catalog Number AB35SX050040135
Product Catalog Number AB35SX050040135
Sheath size
  • 6F
Rated burst pressure
  • 18 atm
Shaft length
  • 135 mm
Nominal pressure
  • 10 atm
Balloon length
  • 40 mm
Balloon diameter
  • 5 mm
Product Catalog Number AB35SX050060135
Product Catalog Number AB35SX050060135
Sheath size
  • 6F
Nominal pressure
  • 10 atm
Rated burst pressure
  • 18 atm
Balloon diameter
  • 5 mm
Balloon length
  • 60 mm
Shaft length
  • 135 mm
Product Catalog Number AB35SX040120135
Product Catalog Number AB35SX040120135
Shaft length
  • 135 mm
Balloon length
  • 120 mm
Balloon diameter
  • 4 mm
Nominal pressure
  • 10 atm
Rated burst pressure
  • 20 atm
Sheath size
  • 6F
Product Catalog Number AB35SX050120135
Product Catalog Number AB35SX050120135
Nominal pressure
  • 10 atm
Rated burst pressure
  • 16 atm
Balloon length
  • 120 mm
Balloon diameter
  • 5 mm
Shaft length
  • 135 mm
Sheath size
  • 6F
Product Catalog Number AB35SX040060080
Product Catalog Number AB35SX040060080
Balloon length
  • 60 mm
Balloon diameter
  • 4 mm
Shaft length
  • 80 mm
Sheath size
  • 6F
Nominal pressure
  • 10 atm
Rated burst pressure
  • 20 atm
Product Catalog Number AB35SX040040135
Product Catalog Number AB35SX040040135
Rated burst pressure
  • 20 atm
Sheath size
  • 6F
Balloon length
  • 40 mm
Shaft length
  • 135 mm
Balloon diameter
  • 4 mm
Nominal pressure
  • 10 atm
Product Catalog Number AB35SX060080080
Product Catalog Number AB35SX060080080
Nominal pressure
  • 8 atm
Shaft length
  • 80 mm
Sheath size
  • 6F
Balloon length
  • 80 mm
Balloon diameter
  • 6 mm
Rated burst pressure
  • 14 atm
Product Catalog Number AB35SX060060135
Product Catalog Number AB35SX060060135
Sheath size
  • 6F
Balloon length
  • 60 mm
Shaft length
  • 135 mm
Rated burst pressure
  • 14 atm
Nominal pressure
  • 8 atm
Product Catalog Number AB35SX050060080
Product Catalog Number AB35SX050060080
Balloon diameter
  • 5 mm
Sheath size
  • 6F
Nominal pressure
  • 10 atm
Balloon length
  • 60 mm
Shaft length
  • 80 mm
Rated burst pressure
  • 18 atm
Product Catalog Number AB35SX060100080
Product Catalog Number AB35SX060100080
Balloon Diameter
  • 6 mm
Sheath Size
  • 6F
Balloon Length
  • 100 mm
Rated Burst Pressure
  • 14 atm
Shaft Length
  • 80 mm
Nominal Pressure
  • 8 atm
  • 1. Lyden S, ILLUMENATE trial update, oral presentation, AMP Aug 2019.. Granada JF. Future directions, clinical applications and local drug delivery technologies. Presented at the Transcatheter Cardiovascular Therapeutics (TCT) 25th Annual Scientific Symposium; October 27-November 1, 2013; San Francisco, California. Slide 7, 15.
  • 2. Mathews SJ, Stellarex in the Treatment of the SFA and Popliteal: Late- Breaking 3-Year Data, oral presentation, NCVH June 2019.
  • 3. Lyden S, Safety And Effectiveness Of The Stellarex DCB With Low Dose Paclitaxel: 4 Year Results from the ILLUMENATE Pivotal trial, oral presentation, LINC Jan 2020, Leipzig, Germany.
  • 4. Laird, et al. J Am Coll Cardio. 2015;66:2329-2338. In.Pact Summary of Safety and Effectiveness Data (SSED). Medtronic In.Pact Instructions for Use, M052624T001 Rev 1F.
  • 5. Bard Lutonix Instructions for Use, BAW1387400r3.
  • 6. Holden A. Comparing Trials Data in the Management of Calcified Arteries. Charing Cross 2018. April 24-26, 2018; London, UK.
  • 7. Gray WA, Mortality assessment of ptx coated balloons - patient-level meta-analysis of the ILLUMENATE clinical program at 3 years, Circulation, 140:1145-1155, Oct 2019 1.
  • 8. Lyden, S. LINC, 2019. Long-term safety data from the Stellarex DCB program Jan. 22, 2019. Leipzig, Germany.
  • 9. Lyden S, Safety And Effectiveness Of The Stellarex DCB With Low Dose Paclitaxel: 4 Year Results from the ILLUMENATE Pivotal trial, oral presentation, LINC Jan 2020, Leipzig, Germany.
  • 10. Diamantopoulos A, Gupta Y, Zayed H, KatsanosK. Paclitaxel-coated balloons and aneurysm formation in peripheral vessels. J VascSurg. 2015 Nov;62(5):1320-2.
  • 11. Schmidt A et al. First experience with drug-eluting balloons in infrapoplitealarteries: restenosis rate and clinical outcome. J Am Coll Cardiol. 2011 Sep 6;58(11):1105-9.
  • 12. LiistroF et al. Drug-eluting balloon in peripheral intervention for below the knee angioplasty evaluation (DEBATE-BTK): a randomized trial in diabetic patients with critical limb ischemia. Circulation. 2013 Aug 6;128(6):615-21.
  • 13. Zeller T, et al. IN.PACT DEEP Trial Investigators. Drug-eluting balloon versus standard balloon angioplasty for infrapoplitealarterial revascularization in critical limb ischemia: 12-month results from the IN.PACT DEEP randomized trial. J Am Coll Cardiol. 2014 Oct 14;64(15):1568-76.
  • 14. Venkatasubbu GD, et al. Surface modification and paclitaxel drug delivery of folic acid modified polyethylene glycol functionalized hydroxyapatite nanoparticles. Powder Technology. 2013;235:437-442.
  • 15. Granada JF. Future directions, clinical applications and local drug delivery technologies. Presented at the Transcatheter Cardiovascular Therapeutics (TCT) 25th Annual Scientific Symposium; October 27-November 1, 2013; San Francisco, California. Slide 7, 15.
  • 16. Stellarex: Data on file. Spectranetics Document. 2014. Spectranetics Pre-clinical Animal Study ADO097.
  • 17. Gray B, Safety And Efficacy Of The Stellarex DCB With Low Dose Paclitaxel - 4 Year Results from the ILLUMENATE EU RCT, Viva Late Breaking Clinical Trials, 25 June 2020.
  • *Complex patients refers to high rates of severe calcium, diabetes and renal insufficiency. Primary patency based on Kaplan-Meier estimates.
  • †† No statistically significant difference in mortality
  • ‡Data from independent CEC (clinical events committee) adjudication of all events resulting in death across all studies Product availability is subject to country regulatory clearance. Please contact your local sales representative to check the availability in your country.