SmartPath upgrades and
trade-ins for CT
We regularly develop advances in CT scanner design and technology to help give you the speed and performance to do more. SmartPath for CT allows you to upgrade your existing equipment so you can extend its lifecycle and take advantage of new techniques for outstanding image quality and low dose.
With a SmartPath upgrade you can benefit from our advanced reconstruction technology – IMR, or iterative model reconstruction.
IMR allows you to combine virtually noise-free images and industry-leading low-contrast resolution with significantly lower doses[1]. And reconstruction time for the majority of reference protocols is less than 3 minutes*.
* Requires IMR Platinum: IMR Platinum has the additional benefit of reconstructing gated acquisitions (ECG- and pulmonary-gated) - IMR Cardiac
* May require prerequisite upgrade for eligibility
iCT
iCT SP
Ingenuity CT
Ingenuity Core128
Ingenuity Core
Brilliance CT 64-channel with Essence technology
Every patient is different. Philips iPatient offers you patient-specific methods for optimal* management of both image quality and dose. This control allows for better scan-to-scan consistency. You save time too. Scan times are automatically reduced and exam times shortened, in some cases up to 24% with 66% fewer clicks[2]. And iPatient is built to take advantage of future discoveries.
*”Optimal” refers to the use of strategies and techniques that facilitate the management and control of both image quality and dose
iPatient offers you personalized control of your CT scans on a patient by patient basis
* May require prerequisite upgrade for eligibility
iCT
iCT SP
Ingenuity Core128
Ingenuity Core
Brilliance CT 64-channel with Essence technology
Interested in learning more about our SmartPath solutions in computed tomography and how you can enhance your equipment’s performance? Sign up for our email list and receive more specific information or a tailored offering.
[1] In clinical practice, the use of IMR may reduce CT patient dose depending on the clinical task, patient size, anatomical location, and clinical practice. A consultation with a radiologist and a physicist should be made to determine the appropriate dose to obtain diagnostic image quality for the particular clinical task. Lower image noise, improved spatial resolution, improved low-contrast detectability, and/or dose reduction were tested using reference body protocols. All metrics were tested on phantoms. Dose reduction assessments were performed using 0.8 mm slices, and tested on the MITA CT IQ Phantom (CCT183, The Phantom Laboratory), using human observers. Data on file [2] In a study done using multiphasic liver CT exams the iPatient software platform reduced time-to-results by 24% and clicks per exam by 66%. Impact of workflow tools in reducing total exam and user interaction time - 4 phase liver computed tomography exams. Nicholas Ardley - Southern Health, Kevin Buchan - Philips Healthcare, Ekta Dharaiya - Philips Healthcare.