Goldway  Bedside patient monitor

Goldway G40E

Bedside patient monitor

Find similar products

Clinicians need to respond swiftly to rapid changes in their patient's condition. Having a highly reliable, versatile patient monitoring solution on hand saves precious time in determining the best course of care. G40E is your choice for a cost-effective, easy to learn, pre-configured bedside monitor that provides reliable measurements (Philips ST/AR ECG and FAST-SpO₂).

Features
Advanced functionalities

Advanced functionalities

To accommodate different clinical environments, the G40E delivers real-time data about cardiac and respiratory conditions. In addition to basic monitoring parameters, such as Philips ST/AR 3- and 5-lead ECG/ respiration, NBP, 2 temperatures, and Philips SpO₂/PR, ST and arrhythmia monitoring, it also provides 2-channel invasive blood pressure and Microstream etCO₂ monitoring as options.
Ease of use

Ease of use

The monitor has a 12.1” display with flexible display modes, such as big number display, minitrend, OxyCRG, as well as auto waveform channel height adjustment function to fit various clinical settings. Intuitive menus, fixed key access, bright color screen and optional touchscreen were all designed for maximum ease of use.
Networking and data management

Networking and data management

The G40E comes standard with LAN networking capabilities for facilities looking to create a network with a bi-directional communication with Philips Efficia CMS200 central monitoring system or require data output in HL7 format.
Compact and cost-effective

Compact and cost-effective

Built according to Philips exacting quality standards, the G40E patient monitor offers market-proven essential parameters in a compact, cost-effective monitor to provide accurate measurement results upon your tight budget. The alarm latch function helps reduce alarm fatigue to form a silent care environment.
Works with Efficia consumables

Works with Efficia consumables

The G40E patient monitor is designed to be compatible with Philips Efficia consumables, which are also used on Philips Efficia CM series patient monitors, to lower your total cost of ownership by sharing Philips consumables across different care settings.
  • Advanced functionalities
  • Ease of use
  • Networking and data management
  • Compact and cost-effective
See all features
Advanced functionalities

Advanced functionalities

To accommodate different clinical environments, the G40E delivers real-time data about cardiac and respiratory conditions. In addition to basic monitoring parameters, such as Philips ST/AR 3- and 5-lead ECG/ respiration, NBP, 2 temperatures, and Philips SpO₂/PR, ST and arrhythmia monitoring, it also provides 2-channel invasive blood pressure and Microstream etCO₂ monitoring as options.
Ease of use

Ease of use

The monitor has a 12.1” display with flexible display modes, such as big number display, minitrend, OxyCRG, as well as auto waveform channel height adjustment function to fit various clinical settings. Intuitive menus, fixed key access, bright color screen and optional touchscreen were all designed for maximum ease of use.
Networking and data management

Networking and data management

The G40E comes standard with LAN networking capabilities for facilities looking to create a network with a bi-directional communication with Philips Efficia CMS200 central monitoring system or require data output in HL7 format.
Compact and cost-effective

Compact and cost-effective

Built according to Philips exacting quality standards, the G40E patient monitor offers market-proven essential parameters in a compact, cost-effective monitor to provide accurate measurement results upon your tight budget. The alarm latch function helps reduce alarm fatigue to form a silent care environment.
Works with Efficia consumables

Works with Efficia consumables

The G40E patient monitor is designed to be compatible with Philips Efficia consumables, which are also used on Philips Efficia CM series patient monitors, to lower your total cost of ownership by sharing Philips consumables across different care settings.

Specifications

Safety approval and quality system
Safety approval and quality system
Water proof
  • IPX1
Safety standard
  • IEC 60601-1-2:2014
Quality system
  • ISO9001 & ISO13485 certified CE marking according to the Council Directive 93/42/EEC
Electromagnetic environment
  • IEC 60601-1-2:2000/A1:2014
Power supply
Power supply
Battery
  • Rechargeable Li-Ion battery Maximum 2.5 hour continuous monitoring (1 battery)
AC power input
  • 100 - 240 VAC, 50/60 Hz
ECG
ECG
Pacemaker detection
  • Yes
Lead selection, 5-lead
  • I, II, III, aVR, aVL, aVF, V
ST measurement range
  • -2.5 mV - +2.5 mV
Waveform speed
  • 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s
HR measurement
  • Adult / pediatric: 15 bpm - 300 bpm Neonatal: 15 bpm - 300 bpm Step: 1 bpm
Lead selection, 3-lead
  • I, II, III
HR accuracy
  • ±5 bpm or ±1 %, whichever is greater
Lead type
  • 3-lead or 5-lead selectable
Arrhythmia
  • 21 calls
Gain selection
  • x 1/4, x 1/2, x 1, x 2, x 4, Auto
Protection
  • Against electrosurgical interference and defibrillation
Display
Display
Size
  • 10.4+611:631"
Resolution
  • 800 x 600 pixels
Type
  • Color TFT LCD, 4:3
Channels
  • Max 11 channels (auto waveform channel height adjustment)
Data review and storage
Data review and storage
Data review and storage
  • 1600- NBP data, 1200 hr trend graph, 120 min full disclosure ECG 1, 200 - alarm & arrhythmia events
SpO2 (Philips SpO2 technology)
SpO2 (Philips SpO2 technology)
Waveform speed
  • 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Pulse rate accuracy
  • ±2 bpm or ±2%, whichever is greater
Pulse rate range
  • 30 bpm - 300 bpm
Perfusion index
  • Yes
Accuracy
  • 70 % - 100 %, depends on sensor; 0 - 69 %, unspecified
Measurement range
  • 0 - 100 %
Weight and dimensions
Weight and dimensions
Dimensions (w x d x h)
  • 316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.)
Net weight
  • Approx. 3.5 kg without battery
Temperature (TEMP, 2-channel)
Temperature (TEMP, 2-channel)
Measurement range
  • 0 - 50℃ (32℉ - 122℉)
Resolution
  • 0.1℃ (0.2℉)
Accuracy
  • ±0.1℃ (±0.2℉) (without sensor)
Units
  • ℃ / ℉
Minimum measuring time
  • Attachable skin surface probe: less than 10 minutes Esophageal/rectal probe: less than 2 minutes
Invasive Blood Pressure
Invasive Blood Pressure
Accuracy
  • ±4 mmHg (0.53 kPa) or ±4 % of reading, whichever is greater
Invasive blood pressure (IBP, 2-channel, optional)
Invasive blood pressure (IBP, 2-channel, optional)
Waveform speed
  • 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Measurement range
  • -50 - 400 mmHg (-6.6 kPa - 53.3 kPa)
Parameters
  • SYS/DIA/MAP/Pulse Rate
Units
  • mmHg/kPa/cmH₂O
Resolution
  • 1 mmHg (0.13 kPa)
Pulse rate range
  • 30 bpm – 254 bpm
Pulse rate accuracy
  • ±2bpm or ±2%, whichever is greater
Transducer sensitivity
  • 5 uV/V/mmHg
Sampling rate
  • 62.5 samples per second
Respiration (RESP)
Respiration (RESP)
Work mode
  • Auto or manual (threshold)
Accuracy
  • 0rpm – 120rpm: ±1 rpm; 121rpm – 150rpm: ±2 rpm
Measurement method
  • Thoracic impedance
Gain selection
  • x 1/2, x 1, x 2
Apnea alarm
  • Yes, 10 - 60 s
Waveform speed
  • 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s Accuracy undefined
Measurement range
  • 0 rpm - 150 rpm
RESP lead
  • RA-LL
Cardiac Output (optional)
Cardiac Output (optional)
Measurement range
  • 0.1 l/min - 20.0 l/min
Blood temperature range
  • 27℃ - 43℃ (80.6℉ - 109.4℉)
Injection temperature
  • 0℃ - 27℃ (32℉ - 80.6℉)
Measurement accuracy
  • ±0.2 l/min or ±10 %, whichever is greater
Blood temperature accuracy
  • ± 0.1℃
Measurement method
  • Right heart thermodilution
Non-invasive blood pressure (NBP)
Non-invasive blood pressure (NBP)
Diastolic measurement range, neonate
  • 10 mmHg - 110 mmHg (1.3 kPa - 14.7 kPa)
Diastolic measurement range, adult / pediatric
  • 10 mmHg - 220 mmHg (1.3 kPa - 29.3 kPa)
Cuff pressure range, adult / pediatric
  • 0 - 300 mmHg ( 0 kPa - 40.0 kPa)
Operating mode
  • Manual/Auto/STAT
MAP measurement range, adult / pediatric
  • 20 mmHg – 235 mmHg (2.7 kPa – 31.3 kPa)
Systolic measurement range, adult/ pediatric
  • 30 mmHg - 254 mmHg (4.0 kPa - 33.9 kPa)
Accuracy, maximum standard deviation
  • 8 mmHg (1.1 kPa)
MAP measurement range, neonate
  • 20 mmHg – 125mmHg (2.7 kPa – 16.7kPa)
Accuracy, mean error
  • ±5 mmHg (±0.7 kPa)
Auto measure intervals
  • 3, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes
Units
  • mmHg/kPa
Cuff pressure range, neonate
  • 0 - 150 mmHg ( 0 kPa - 20.0 kPa)
Systolic measurement range, neonate
  • 30 mmHg - 135 mmHg (4.0 kPa - 18.0 kPa)
Method
  • Automatic oscillometric
Parameters
  • SYS/DIA/MAP/Pulse Rate
Pulse rate accuracy
  • ±5bpm or ±5%, whichever is greater
Pulse rate range
  • 40 bpm – 240 bpm
Capnopgraphy (etCO2, optional)
Capnopgraphy (etCO2, optional)
awRR accuracy, 3 rpm – 70 rpm
  • ±1 rpm
awRR accuracy, 121 rpm – 150 rpm
  • ±3 rpm
awRR accuracy, 71 rpm – 120 rpm
  • ±2 rpm
Measurement range
  • 0 - 99 mmHg (0 kPa - 13.2 kPa)
Method
  • Microstream, infrared absorption (Oridion)
Accuracy, 39 mmHg – 99 mmHg (5.2 kPa – 13.2 kPa)
  • ± (5% of reading + 0.08% for every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa)
Accuracy+C781, 0 – 38 mmHg (0 kPa – 5.1 kPa)
  • ±2 mmHg (±0.28 kPa)
awRR range
  • 0-150 rpm
Parameters
  • awRR, etCO₂, inCO₂
Recorder (optional)
Recorder (optional)
Type
  • Built-in thermal recorder, 3 channels
Print speed
  • Auto, 12.5 mm/s, 25 mm/s, 50 mm/s
Print mode
  • Real-time recording, timed recording, alarm-activated recording
External interface (standard)
External interface (standard)
External interface
  • ECG analog output VGA output Nurse call LAN USB
Safety approval and quality system
Safety approval and quality system
Water proof
  • IPX1
Safety standard
  • IEC 60601-1-2:2014
Power supply
Power supply
Battery
  • Rechargeable Li-Ion battery Maximum 2.5 hour continuous monitoring (1 battery)
AC power input
  • 100 - 240 VAC, 50/60 Hz
See all specifications
Safety approval and quality system
Safety approval and quality system
Water proof
  • IPX1
Safety standard
  • IEC 60601-1-2:2014
Quality system
  • ISO9001 & ISO13485 certified CE marking according to the Council Directive 93/42/EEC
Electromagnetic environment
  • IEC 60601-1-2:2000/A1:2014
Power supply
Power supply
Battery
  • Rechargeable Li-Ion battery Maximum 2.5 hour continuous monitoring (1 battery)
AC power input
  • 100 - 240 VAC, 50/60 Hz
ECG
ECG
Pacemaker detection
  • Yes
Lead selection, 5-lead
  • I, II, III, aVR, aVL, aVF, V
ST measurement range
  • -2.5 mV - +2.5 mV
Waveform speed
  • 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s
HR measurement
  • Adult / pediatric: 15 bpm - 300 bpm Neonatal: 15 bpm - 300 bpm Step: 1 bpm
Lead selection, 3-lead
  • I, II, III
HR accuracy
  • ±5 bpm or ±1 %, whichever is greater
Lead type
  • 3-lead or 5-lead selectable
Arrhythmia
  • 21 calls
Gain selection
  • x 1/4, x 1/2, x 1, x 2, x 4, Auto
Protection
  • Against electrosurgical interference and defibrillation
Display
Display
Size
  • 10.4+611:631"
Resolution
  • 800 x 600 pixels
Type
  • Color TFT LCD, 4:3
Channels
  • Max 11 channels (auto waveform channel height adjustment)
Data review and storage
Data review and storage
Data review and storage
  • 1600- NBP data, 1200 hr trend graph, 120 min full disclosure ECG 1, 200 - alarm & arrhythmia events
SpO2 (Philips SpO2 technology)
SpO2 (Philips SpO2 technology)
Waveform speed
  • 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Pulse rate accuracy
  • ±2 bpm or ±2%, whichever is greater
Pulse rate range
  • 30 bpm - 300 bpm
Perfusion index
  • Yes
Accuracy
  • 70 % - 100 %, depends on sensor; 0 - 69 %, unspecified
Measurement range
  • 0 - 100 %
Weight and dimensions
Weight and dimensions
Dimensions (w x d x h)
  • 316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.)
Net weight
  • Approx. 3.5 kg without battery
Temperature (TEMP, 2-channel)
Temperature (TEMP, 2-channel)
Measurement range
  • 0 - 50℃ (32℉ - 122℉)
Resolution
  • 0.1℃ (0.2℉)
Accuracy
  • ±0.1℃ (±0.2℉) (without sensor)
Units
  • ℃ / ℉
Minimum measuring time
  • Attachable skin surface probe: less than 10 minutes Esophageal/rectal probe: less than 2 minutes
Invasive Blood Pressure
Invasive Blood Pressure
Accuracy
  • ±4 mmHg (0.53 kPa) or ±4 % of reading, whichever is greater
Invasive blood pressure (IBP, 2-channel, optional)
Invasive blood pressure (IBP, 2-channel, optional)
Waveform speed
  • 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Measurement range
  • -50 - 400 mmHg (-6.6 kPa - 53.3 kPa)
Parameters
  • SYS/DIA/MAP/Pulse Rate
Units
  • mmHg/kPa/cmH₂O
Resolution
  • 1 mmHg (0.13 kPa)
Pulse rate range
  • 30 bpm – 254 bpm
Pulse rate accuracy
  • ±2bpm or ±2%, whichever is greater
Transducer sensitivity
  • 5 uV/V/mmHg
Sampling rate
  • 62.5 samples per second
Respiration (RESP)
Respiration (RESP)
Work mode
  • Auto or manual (threshold)
Accuracy
  • 0rpm – 120rpm: ±1 rpm; 121rpm – 150rpm: ±2 rpm
Measurement method
  • Thoracic impedance
Gain selection
  • x 1/2, x 1, x 2
Apnea alarm
  • Yes, 10 - 60 s
Waveform speed
  • 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s Accuracy undefined
Measurement range
  • 0 rpm - 150 rpm
RESP lead
  • RA-LL
Cardiac Output (optional)
Cardiac Output (optional)
Measurement range
  • 0.1 l/min - 20.0 l/min
Blood temperature range
  • 27℃ - 43℃ (80.6℉ - 109.4℉)
Injection temperature
  • 0℃ - 27℃ (32℉ - 80.6℉)
Measurement accuracy
  • ±0.2 l/min or ±10 %, whichever is greater
Blood temperature accuracy
  • ± 0.1℃
Measurement method
  • Right heart thermodilution
Non-invasive blood pressure (NBP)
Non-invasive blood pressure (NBP)
Diastolic measurement range, neonate
  • 10 mmHg - 110 mmHg (1.3 kPa - 14.7 kPa)
Diastolic measurement range, adult / pediatric
  • 10 mmHg - 220 mmHg (1.3 kPa - 29.3 kPa)
Cuff pressure range, adult / pediatric
  • 0 - 300 mmHg ( 0 kPa - 40.0 kPa)
Operating mode
  • Manual/Auto/STAT
MAP measurement range, adult / pediatric
  • 20 mmHg – 235 mmHg (2.7 kPa – 31.3 kPa)
Systolic measurement range, adult/ pediatric
  • 30 mmHg - 254 mmHg (4.0 kPa - 33.9 kPa)
Accuracy, maximum standard deviation
  • 8 mmHg (1.1 kPa)
MAP measurement range, neonate
  • 20 mmHg – 125mmHg (2.7 kPa – 16.7kPa)
Accuracy, mean error
  • ±5 mmHg (±0.7 kPa)
Auto measure intervals
  • 3, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes
Units
  • mmHg/kPa
Cuff pressure range, neonate
  • 0 - 150 mmHg ( 0 kPa - 20.0 kPa)
Systolic measurement range, neonate
  • 30 mmHg - 135 mmHg (4.0 kPa - 18.0 kPa)
Method
  • Automatic oscillometric
Parameters
  • SYS/DIA/MAP/Pulse Rate
Pulse rate accuracy
  • ±5bpm or ±5%, whichever is greater
Pulse rate range
  • 40 bpm – 240 bpm
Capnopgraphy (etCO2, optional)
Capnopgraphy (etCO2, optional)
awRR accuracy, 3 rpm – 70 rpm
  • ±1 rpm
awRR accuracy, 121 rpm – 150 rpm
  • ±3 rpm
awRR accuracy, 71 rpm – 120 rpm
  • ±2 rpm
Measurement range
  • 0 - 99 mmHg (0 kPa - 13.2 kPa)
Method
  • Microstream, infrared absorption (Oridion)
Accuracy, 39 mmHg – 99 mmHg (5.2 kPa – 13.2 kPa)
  • ± (5% of reading + 0.08% for every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa)
Accuracy+C781, 0 – 38 mmHg (0 kPa – 5.1 kPa)
  • ±2 mmHg (±0.28 kPa)
awRR range
  • 0-150 rpm
Parameters
  • awRR, etCO₂, inCO₂
Recorder (optional)
Recorder (optional)
Type
  • Built-in thermal recorder, 3 channels
Print speed
  • Auto, 12.5 mm/s, 25 mm/s, 50 mm/s
Print mode
  • Real-time recording, timed recording, alarm-activated recording
External interface (standard)
External interface (standard)
External interface
  • ECG analog output VGA output Nurse call LAN USB